Assessment of indoor and outdoor airborne fungi in an Educational, Research and Treatment Center

  • Nasrin Rostami Environmental Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran, Islamic Republic of.
  • Hossien Alidadi Environmental Health Department, Health Sciences Research Center, School of Health, Mashhad University of Medical Sciences, Mashhad, Iran, Islamic Republic of.
  • Hossein Zarrinfar | Zarrinfarh@mums.ac.ir Allergy Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad; Department of Parasitology and Mycology, Ghaem Hospital, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran, Islamic Republic of.
  • Pegah Salehi Environmental Health Engineering, School of Health, Esfahan University of Medical Sciences, Esfahan, Iran, Islamic Republic of.

Abstract

Hospital environments contain different types of microorganisms. Airborne fungi are one of these microbes and the major source of hospital indoor contamination that will be able to cause airborne fungal diseases. In the current study, the total count and diversity of the airborne filamentous and yeasts fungi were investigated in indoor and outdoor air of selective wards of Emam Reza Educational, Research and Treatment Center. This cross-sectional study was performed during the fall season. One hundred and ninety-two environmental samples of indoor and outdoor air from hematology, infectious diseases, Ear, Nose and Throat (ENT) and Neonatal Intensive Care Unit (NICU) wards were collected by open plate technique (on Sabouraud dextrose agar media) once a week. The cultures were then examined and evaluated according to macroscopic and microscopic examination criteria. In this study, 67 (62.03%) of indoor samples and 81 (96.42%) of outdoor samples were positive for fungi. The most isolated fungi were yeast species (17.12%), Penicillium spp. (16.34%), Alternaria spp. (14.39%), Aspergillus niger (11.28%), A. flavus (8.95%), respectively. Almost all of the wards showed high rates of contamination by various fungi. However, the analysis of the data showed that indoor air of hematology ward had the highest fungal pollution. In contrast, the outdoor air of ENT had the highest fungal pollution. Thus, these results demonstrated that the cleansing and disinfection procedures in the hospital wards should be improved yet.

Dimensions

Altmetric

PlumX Metrics

Downloads

Download data is not yet available.

Author Biography

Hossein Zarrinfar, Allergy Research Center, School of Medicine, Mashhad University of Medical Sciences, Mashhad; Department of Parasitology and Mycology, Ghaem Hospital, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad
Medical Mycology and Parasitology
Published
2016-06-17
Info
Issue
Section
Original Articles
Keywords:
Hospital wards, bio-aerosol, airborne fungal, Mashhad.
Statistics
  • Abstract views: 1746

  • PDF: 962
  • HTML: 987
How to Cite
Rostami, N., Alidadi, H., Zarrinfar, H., & Salehi, P. (2016). Assessment of indoor and outdoor airborne fungi in an Educational, Research and Treatment Center. Italian Journal of Medicine, 11(1), 52-56. https://doi.org/10.4081/itjm.2016.663