Reproducibility and inter-observer variability of the internal jugular vein ultrasonographic assessment: a multicenter cross-sectional study
Abstract
This study evaluates inter-observer variability in measuring internal jugular vein (IJV) ultrasonographic parameters using images obtained from medical ward patients. A cross-sectional study was conducted across 4 Italian hospitals. After brief training, 8 expert sonographers and 11 novices measured at the supraclavicular, cricoid, and submandibular levels the anteroposterior expiratory maximum diameter (AP-IJV max), maximum cross-sectional area (CSA-IJV max), aspect ratio (AP-IJV max to latero-lateral diameter), and collapsibility index (IJV-c) on 60 IJV ultrasound images from 10 patients. Inter-observer reliability was assessed using the intraclass correlation coefficient. No significant differences were observed between experts and novices for AP-IJV max, CSA-IJV max, or aspect ratio across the different views. The lowest inter-examiner variability was found for AP-IJV max and CSA-IJV max at the supraclavicular level. Aspect ratio showed moderate reliability among experts but poor reproducibility among novices. The IJV-c demonstrated the highest inter-examiner variability in both groups. To our knowledge, this is the first multicenter study aimed at evaluating the reliability of different non-invasive acoustic measurements and windows to better identify IJV dimensions, mainly in case of hypovolemia or fluid challenge. The AP-IJV max and the CSA-IJV max measurements showed excellent inter-observer reproducibility, suggesting the use of point-of-care ultrasound protocols for non-invasive volume assessment, particularly at the neck’s base or cricoid level.
References
- Wang MK, Piticaru J, Kappe C, et al. Internal jugular vein ultrasound for the diagnosis of hypovolemia and hypervolemia in acutely ill adults: a systematic review and meta-analysis. Intern Emerg Med 2022;17:1521-32. DOI: https://doi.org/10.1007/s11739-022-03003-y
- Parenti N, Scalese M, Palazzi C, et al. Role of internal jugular vein ultrasound measurements in the assessment of central venous pressure in spontaneously breathing patients: a systematic review. J Acute Med 2019;9:39-48.
- Simon MA, Kliner DE, Girod JP, et al. Detection of elevated right atrial pressure using a simple bedside ultrasound measure. Am Heart J 2010;159:421-7. DOI: https://doi.org/10.1016/j.ahj.2010.01.004
- Simon MA, Schnatz RG, Romeo JD, Pacella JJ. Bedside ultrasound assessment of jugular venous compliance as a potential point-of-care method to predict acute decompensated heart failure 30-day readmission. J Am Heart Assoc 2018;7:e009185. DOI: https://doi.org/10.1161/JAHA.117.008184
- Tzadok B, Shapira S, Tal-Or E. Ultrasound of jugular veins for assessment of acute dyspnea in emergency departments and for the assessment of acute heart failure. Isr Med Assoc J 2020;20:308-10.
- Vaidya GN, Ghafghazi S. Correlation of internal jugular and subclavian vein diameter variation on bedside ultrasound with invasive right heart catheterization. Indian Heart J 2021;73:231-5. DOI: https://doi.org/10.1016/j.ihj.2021.01.024
- Ammirati E, Marchetti D, Colombo G, et al. Estimation of right atrial pressure by ultrasound-assessed jugular vein distensibility in patients with heart failure. Circ Heart Fail 2024;17:e010973. DOI: https://doi.org/10.1161/CIRCHEARTFAILURE.123.010973
- Albaeni A, Sharma M, Ahmad M, Khalife WI. Accurate estimation of right-filling pressure using handheld ultrasound score in patients with heart failure. Am J Med 2022;135:634-40. DOI: https://doi.org/10.1016/j.amjmed.2021.11.020
- Parenti N, Bastiani L, Tripolino C, Bacchilega I. Ultrasound imaging and central venous pressure in spontaneously breathing patients: a comparison of ultrasound-based measures of internal jugular vein and inferior vena cava. Anaesthesiol Intensive Ther 2022;54:150-5. DOI: https://doi.org/10.5114/ait.2022.114469
- Donahue SP, Wood JP, Patel BM, Quinn JV. Correlation of sonographic measurements of the internal jugular vein with central venous pressure. Am J Emerg Med 2009;27:851-5. DOI: https://doi.org/10.1016/j.ajem.2008.06.005
- Von Elm E, Altman DG, Egger M, et al. The strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies. J Clin Epidemiol 2008;61:344-9. DOI: https://doi.org/10.1016/j.jclinepi.2007.11.008
- Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med 2016;15:155-63. DOI: https://doi.org/10.1016/j.jcm.2016.02.012
- Arifin WN. Sample size calculator. Available from: http://wnarifin.github.io.
- Parenti N, Palazzi C, Parenti M, D’Addato S. Could internal jugular vein ultrasound be useful in the assessment of patients with heart failure? A systematic review. Ital J Med 2024;18:1726. DOI: https://doi.org/10.4081/itjm.2024.1726
- Dávila-Román VG, Toenjes AK, Meyers RM, et al. Ultrasound core laboratory for the household air pollution intervention network trial: standardized training and image management for field studies using portable ultrasound in fetal, lung, and vascular evaluations. Ultrasound Med Biol 2021;47:1506-13. DOI: https://doi.org/10.1016/j.ultrasmedbio.2021.02.015
- Yaegashi H, Watanabe T, Kaoku S, et al. Remote breast ultrasound image interpretation system for multicenter study (JABTS BC-04 study). Ultrasound Med Biol 2017;43:S320. DOI: https://doi.org/10.1016/j.ultrasmedbio.2017.08.948
- US Food and Drug Administration. Clinical trial imaging endpoint process standards: guidance for industry. 2018. Available from: https://www.fda.gov/media/81172/download.
Metrics
Citations and online attention from Dimensions, Altmetric and PlumX.
License
Copyright (c) 2026 the Author(s)

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
PAGEPress has chosen to apply the Creative Commons Attribution NonCommercial 4.0 International License (CC BY-NC 4.0) to all manuscripts to be published.